MLD Methane

Gas Detectors

 
  • media/djcatalog2/images/item/10/mld-methane.1.png
  • NEW !
Manufacturer: GVZ Components

Gas Leakage detector for Methane (CH4)

    • Factory calibrated - No field calibration required
    • No cross sensitivity
    • Immune to poisoning
    • MPS technology inside
    • Long lifetime 15+ years
    • Fail safe (built-in diagnostic)
    • Temperature humidity and pressure compensation
    • Operating range -40° to 75° C, 0-100% Rh
    • IP 65
    • Modbus, 2x Relays and 2x Analogue Output (ALL IN ONE)
    • In Flame Start feature
Services

Professional and fast quote

Product usually available on stock

Check availability and GET A QUOTE by clicking the button below

Delivery:  
  • ASK for "Just in time" delivery

More questions?

Description


MLD methane detector

MLD gas detector for methane based on NevadaNano MPS Technology

The MLD gas detectors for methane provides quick and accurate detection of methane across a variety of industries — from the oil and gas supply chain to safety applications. The smart sensor is intrinsically safe, robust, and extremely poison-resistant.
It has built-in environmental compensation and self-testing for fail-safe operation. 
Sensor output are available through Digital: Modbus (RS-485) and Analog: 4-20mA and Analog: 0.4-2V and 2x Dry Contacts: Alarm Relay for LOW conc. - Alarm Relay for HIGH conc./FAULT 
MLD Extended Range Methane detector is designed and optimized for open-air detection of methane and natural gas plumes over a full range of concentrations, from 50 to 1,000,000 ppm.
Note: the MLD Extended Range Methane is not suited for safety applications or for detection of gradually accumulating concentrations (e.g. slow leaks into confined, poorly ventilated spaces).

TECHNICAL DATA

MLD Flammables with NevadaNano Mini

MLD Flammables with NevadaNano S4

MLD Methane Extended Range with NevadaNano S4

Sensor Technology

Molecular Property Spectrometry

Sensor Type

Mini Flammables

S4 Flammables 4.0

S4 Methane XR

Gas Detected

Methane CH4

Detection Range

0-100% LEL

0-100% LEL

50 - 1,000,000 ppm

Accuracy

±3%

±3%

±10% error (> 300 ppm)

In Flame function

NO

YES - It can detect gas presence at start-up

NO

Outputs

Digital: Modbus (RS-485) - Analog: 4-20mA - Analog: 0.4-2V - Dry Contacts: 2x Alarm Relays (LOW conc. - HIGH conc./FAULT)

Visual information

3 x LED (Status, Alarm LOW, Alarm HIGH/FAULT)

Supply voltage

12 Vdc - 24 Vdc

Power consumption

35mA average - 50mA peak

Dimensions

12.8 x 8.9 x 2,2 cm

12.8 x 8.9 x 3,7 cm

12.8 x 8.9 x 3,7 cm

Operating temperature range

from -40 to +75 ºC

Operating humidity range 0 to 100 %RH
Operating pressure range 80 to 120 kPa
Certifications & Approvals CE, EMC, Rohs, IECEx, IEC60335-2-40, ATEX
EN60079-0, EN60079-11: Intrinsecally Safe device - Gr.II Cat.3G Ex ic IIA/IIC TX Gc
On running tests for SIL1/SIL2  according to EN50402 / IEC50271

Documentation


Via Magenta, 77/16A
20017 Rho (MI) - Italy
Phone +39 02 3340 0846
VAT: IT04126380155
Google Map

Via Magenta, 77/16A
Rho 20017, Italy
This email address is being protected from spambots. You need JavaScript enabled to view it.
+39 02 3340 0846


© 2023 GVZ components srl | All rights reserved