Gas Sensor Module for Refrigerant Detection (R-454b) without case

- Main Features

- Item without case
- Factory pre-calibrated and high reliable module
- Comply with UL60335-2-40 Ed.4
- Easy maintenance with designed life of about 15 years
- Supply voltage: 5Vdc
- Output signal: PWM (alarm set @4% LEL R454b)
- Warm up time: ∼7seconds
- Current consumption: 40mA (initial peak of 80mA)
- Mass production in Q2-2026

Services

---

###### Professional and fast quote

---

###### Product usually available on stock

---

#

- ASK for "Just in time" delivery

### More questions?

[+39 02 3340 0846](https://gvzcomp.it/tel:390233400846) or [Contact us](https://gvzcomp.it/contact)

### Questions?

[+39 02 3340 0846](https://gvzcomp.it/tel:390233400846)
or [Contact us](https://gvzcomp.it/contact)

### Description

As the HVAC-R industry evolves toward greener, safer, and more efficient technologies, reliable refrigerant leak detection is becoming a top priority — not just for safety and regulatory compliance, but also for sustainability. The **FIS5000 series** by **[Nissha FIS Inc](https://gvzcomp.it/brands/nissha-fis).** is a compact, durable, and high-performance family of gas sensor modules designed to detect leaks of common refrigerants such as R32, R454B, and R290, widely used in air conditioning and refrigeration systems.



### Why Use the FIS5000 modules?



✅ **Mandatory Safety Compliance**: In systems using A2L (mildly flammable) and A3 (flammable) class of refrigerants*, leak detection sensors are required by safety regulations.
✅ **Environmental Responsibility**: Fluorocarbon refrigerants are potent greenhouse gases. Early leak detection helps reduce emissions and supports sustainability efforts.
✅ **Long-lasting & Easy to Install**: Designed for extended use in commercial and industrial environments, the sensor is both cost-effective and user-friendly.
✅ **High Sensitivity and Reliability**: Ensures consistent detection performance under real-world operating conditions.
✅ **Excellent value for money** – ideal for cost-sensitive projects.



### Standards Compliance



The sensors are compliant with major international standards for safety and performance:



- UL60335-2-40 Edition 4.0



With a proven track record and compact form factor, the **FIS5000 series** is the ideal solution for OEMs, system integrators, and service professionals seeking reliable refrigerant monitoring solutions.



### The module is available in two configurations:



- **FIS5085-13NC** - Module without case
- **FIS5085-13C1** - Module with case



|   | FIS5085-13C1 | FIS5085-13NC |
| --- | --- | --- |
| Appearance | with case | without case |
| Gas Sensor | SB type semiconductor gas sensor |  |
| Taget Gas | R454b |  |
| Alarm Concentration | R454b @4,000ppm |  |
| Alarm Output | PWM (Open collector) |  |
| Operating and Short Temperature range | -25~60℃(without dew condensation) |  |
| Power Supply | 5.0V DC± 5% |  |
| Average Power Concentration | 40mA |  |
| Dustproof & Waterproof | Moisture-proof paint |  |
| Other Target Gasses※ | R32, R454B, R1234yf, etc |  |



(*) Refrigerants are a gas heat-transfer medium for lowering temperatures. This gas is a critical part of temperature control equipment used in air conditioners, freezers, refrigerators, and other equipment. At the same time, chlorofluorocarbon gas used as a refrigerant is known as a greenhouse gas that has a negative impact on global warming. Society demands reduced emissions of substances that impact climate change for the worse. In the 1980s, scientists began suspecting that HCFCs, then used as a main refrigerant source, contributed to destruction of the ozone layer. The Montreal Protocol, signed in 1987, called for eliminating all HCFCs by the year 2020. Today, HFCs are used as the main source of refrigerants. These chemicals have no impact on the ozone layer; however, when released into the atmosphere, they cause a greenhouse effect that impacts global warming. Beginning in 2019, HFCs have joined the list of regulated chemicals subject to mandatory emissions restrictions. The Nissha gas sensor module for refrigerant detection will play an important role in detecting refrigerant leaks, reduction emissions, and solving this important social issue.

- Filter by Refrigerant R454B
- Applications Safety[HVAC](https://gvzcomp.it/applications/hvac)[Industrial](https://gvzcomp.it/applications/industrial)
- Brands Nissha-FIS®
- Technology MOS
- Type Precalibrated Module

### Documentation

[### Datasheet

PDF | 585.38 KB](https://gvzcomp.it/component/djcatalog2/?format=raw&task=download&fid=3758#.pdf)

### Related products