English English

HVBD Series

High Voltage Battery Disconnect

Main Features

  • Robust metal-ceramic hermetic seal
  • Industry leading dielectric performance
  • High temperature performance
  • Low contact resistance over life
  • Ready for harsh environments
  • Lock-out/tag-out ready for OSHA compliance
  • Drop-in replacement for GIGAVAC(i) HBD Series
  • Optional integrated auxiliary contacts
  • Patent pending

Specifications

Contact Arrangement Form X, SPST
Operating Voltage2 1,000VDC
Dielectric Withstand Voltage 5,000VDC, 1 minute
Continuous Current (107mm2 conductor) 400A, continuous
Overload Current 2,000A, 1 minute
Make and Break (400A @ 24VDC)  5,000 cycles
Voltage Drop (Max at nominal load) 50mV
Min Insulation Resistance 100Mohm
Shock 25G/5ms, 40G/6ms
Vibration (Sinusoidal 18-500Hz Peak) 20G
Operating Temperature-55˚C to 85˚C
Ingress ProtectionExceeds IP69
Weight400g
Case MaterialPA GF Black
Switch Lever MaterialPA GF Red
Mounting100mm | C:C, 2X M8
Mounting PositionAny
Auxiliary Contact – Continuous Current100mA
Auxiliary Contact ArrangementSPDT

Applications AutomotiveAerospace & DefenseTruck, bus & HVORMotorcycles & RVMaterial handlingSafetyClean EnergyIndustrialMarine

Documentation