Skip to main content
  • NEW !
Manufacturer: Sensata Klixon®

Single Phase, High Short Circuit Capacity, "Red" C.B., W/Aux Contacts

  • Trip–free design
  • Single–phase
  • Ambient compensated
  • MIL-DTL-27715 qualified
  • Current rating: 2.5 to 65 amps
  • Long, trouble–free operation: 20,000 operating cycles
  • High vibration resistance
  • High interrupting capacity
Services

Professional and fast quote

Product usually available on stock

  • ASK for "Just in time" delivery

More questions?

Description

KLIXON® 6752-13 series thermal–magnetic circuit breakers are designed and manufactured to meet the more stringent military standards of today’s aircraft electrical systems. The interrupting capacity, vibration resistance and longer cycling life of the 6752-13 series exceed previous military standards. In addition, the 6752-13 series provide ambient compensation, fault coordination of all ratings, and an auxiliary circuits.

Features

  • Trip–free design
  • Single–phase with Aux Contacts
  • Ambient compensated
  • MIL-DTL-27715 qualified
  • Current rating: 2.5 to 65 amps
  • Long, trouble–free operation: 20,000 operating cycles
  • High vibration resistance
  • High interrupting capacity
  • Option available: Auxiliary circuits
  • Circuit protection unaffected by temperature fluctuations (ambient compensated from -53.9°C to 93.3°C)
  • Only faulted line circuits opened (coordination ratings insure that branch circuit breakers trip first under fault conditions)
  • Typical use: Aircraft electrical systems

Specifications

Vibrations 10G minimum, 5–2,000 Hz (other vibration levels available)
Mechanical Shock 25G
Acceleration 10G
Weight 0.2 pound maximum
Interrupt Current 2½–65 amps: 6,000 amps at 30 VDC
2½–50 amps: 6,000 amps at 120 VAC, 400 Hz
65 amps, 3000 amps at 120VAC, 400 Hz
Endurance 5,000 cycles: 120 VAC, 400 Hz inductive
5,000 cycles: 120 VAC, 400 Hz resistive
10,000 cycles: Mechanical, no load
20,000 cycles: Total

Documentation