Skip to main content

REC50 Series

Contactors

 
  • /media/djcatalog2/images/item/10/rec50-series.jpg
     
    Manufacturer: RinconPower
    • Continuous Current: 500A
    • Rated Voltage: 1500 VDC
    • Coil Voltage: 12-36V 
      • 1500V
      • Bi-directional switching
      • Auxiliary contacts
      • Integrated coil economizer
      • Meets RoHS 2011/65/EU
      • UL recognized (File E536110)
    Services

    Professional and fast quote

    Product usually available on stock

    Delivery:  
    • ASK for "Just in time" delivery

    More questions?

    Description

    CHARACTERISTIC

    MEASURE

    Contact Arrangement

    Form X, SPST NO

    Max Switching Voltage

    1,500 VDC

    Dielectric Withstand Voltage Across Open Contacts

    4,500 VAC, 1 minute

    4,500 VDC, 1 minute

    Continuous Current (250mmconductor)

    500A

    Overload Current 1 minute

    1,000A

    30 seconds

    2,000A

    Make and Break

    See table

    Min Insulation Resistance

    1,000 Mohm @ 1,000V

    Contact Voltage Drop (Max)

    50mV @ 100A

    Operate Time (Max, incl bounce)

    40ms

    Release Time (Max)

    12ms

    Shock - Functional, 1/2 Sine, 11ms

    20G

    Shock – Destructive, 1/2 Sine, 11ms

    50G

    Operating Temperature

    -40˚C to 85˚C

    Ingress Protection

    Exceeds IP69, (Hermetically sealed)

    Mechanical life

    200,000

    AUXILIARY CONTACTS

    MEASURE

    Contact Arrangement

    SPST

    Continuous Current

    3A

    Minimum Current

    5mA @ 8V

    COIL

    MEASURE

    Nominal Voltage

    12-36 VDC

    Pick-up Voltage (Max)

    9 VDC

    Drop-out Voltage (Min)

    5 VDC

    Inrush Current (Max)

    3.8A

    Holding Current

    0.34A @ 12 VDC

    0.16A @ 24 VDC

    Documentation