Skip to main content
  • NEW !
Manufacturer: TE Connectivity

Grid Space, High Shock, Double Pole, Magnetic Latching, 2 Amps and Less - M39016/32

    • Special shock designs up to 700 G, 1 ms
    • Suitable for pulse operation
    • No hang up feature on low power pulses
    • Qualified to MIL-R-39016/32
    • Special wiring is available
Services

Professional and fast quote

Product usually available on stock

Delivery:  
  • ASK for "Just in time" delivery

More questions?

Description

This relay has “memory” in that the contact positions do not change when coil power is removed. Switching is accomplished by applying power to the applicable coil (dual coil) or with the applicable polarity (single coil). The low switching power requirements are further enhanced by its ability to operate from capacitor discharge or other pulses or through its own contacts for batteries or similarly limited supplies.

  • Contact Ratings —
    DC resistive — 2 amps at 28 volts
    DC inductive — 0.5 amps at 28 volts,
    200 mH
    AC resistive — 1 amp at 115 volts
    (single coil), case not grounded
    AC resistive — 0.25 amps at 115 volts
    (dual coil), case not grounded
    Low-level — 50 μA at 50 mV
    Peak AC or DC
  • Contact Resistance —
    0.050 ohms initial;
    0.100 ohms after life test
  • Life —
    100,000 operations at rated load;
    1,000,000 at low-level

For further technical details please refer to datasheet below.