MLD Hydrogen

HVAC

 
  • /media/djcatalog2/images/item/10/mld-hydrogen.png
    • NEW !
    Manufacturer: GVZ Components

    Gas Leakage detector for Hydrogen (H2)

      • No field calibration
      • No cross sensitivity
      • Long lifetime 15+ years
      • Fail safe (built-in diagnostic)
      • 0-100% LEL
      • Rh compensation
      • Immune to poisoning
      • Operating range -40° to 75° C, 0-100% Rh
      • Modbus, 2x Relays and 2x Analogue Output (ALL IN ONE)
    Services

    Professional and fast quote

    Product usually available on stock

    Delivery:  
    • ASK for "Just in time" delivery

    More questions?

    Description

    MLD methane detector

    MLD gas detector for Hydrogen with built-in NevadaNano MPS™ technology.

    As the amount of interest and projects for alternative energy solutions based on Hydrogen increase more and more, we couldn't miss the opportunity to provide a reliable detector to prevent hydrogen leakages. 
    Our MLD Hydrogen gas detector with built-in NevadaNano MPS™ Technology is able to ensure high sensitivity, 2 alarms with tuneable thresholds, zero calibration nor maintenance needed, complete poison immunity, constant accuracy and performance for the 15+ years sensor's lifetime.

    SENSOR PERFORMANCES
    Technology Molecular Property Spectrometry™ by NevadaNano
    Gas detected H2
    Response Time (T90) <20 sec.
    Resolution 0,1% LEL
    Lifetime 15+ years

     
    RANGE and ACCURACY
    MLD Gas PN Gas Type Measuring Range Accuracy (0-50 %LEL)
    guaranteed across full environmental range
    (ISO 10156)
    Accuracy @25%LEL
    guaranteed across full environmental range
    (ISO817/ASHRAE 34)
    Accuracy ≤25 %LEL
    @ 20 °C - 50 %RH
    (UL 60335-2-40)
    7 H2 0-100% LEL ± 5% LEL    
     

    OPERATING FEATURES

    Signals Output

    Gas concentration, Temperature, Humidity, Pressure, Status, Prealarm, Alarm, Fault, Lifetime

    Measurament Output

    Digital:  Modbus (RS-485)
    Analog: 4-20mA
    Analog: 0,4-2V
    Dry Contacts: 2x Relays (Alarm1 / Alarm2 / Fault)

    Visual Information

    Visual: 3x LEDs (Status / Alarm1 / Alarm2 / Fault)

    Supply Voltage

    12-24VDC

    Power Consumption

    35mA average - 50mA peak

    Operating Temperature

    -40° to +75°C

    Operating Humidity

    0 - 100% RH

    Operating Pressure

    80 to 120 kPa

    Protection grade

    IP65

    Dimensions MLD-S4

    128 x 89 x 37 mm

    Dimensions MLD-MN

    128 x 89 x 22 mm

    Certifications & Approvals

    CE, EMC, Rohs,  EN60079-0, EN60079-11, ATEX
    SIL2 conformity according to EN50402 / IEC 50271 / IEC 50270 / IEC61508 ongoing

    • Applications
    • Brands
      GVZ Custom Solutions
    • Target Gas
      Hydrogen - H2
    • Type
      Detector
    • Technology
      MPS™
    • Fitting
      Others

    Documentation